• 新しい到着の回入れ墨除去2011q- スイッチndレーザー美容機外因性の顔料のため除去と美白ceと-レーザーの診断装置
    商品番号: 9800516
    仕入れる商品へのお問い合わせについて、
    お電話の場合:スタッフに商品番号をお伝えください。
    商品の詳細

    原産地: 中国(本土) 銘柄: FB モデル番号: D004
    タイプ: レーザーの診断装置 レーザー: Nd: YAG 波長: 1064nm/532nm
    パルスエネルギー: 1-1100Mj 脈拍の持続期間: 10ns 直径: 2-6mm
    冷却装置: 水の風の冷却冷却 純重量: 18のKG 電圧: 220V 50HZ、110V 60HZ

    包装

    包装: アルミボックス

    仕様

     2011 portable Q- switched ND YAG Tattoo Removal Laser Machine D004

    100% good price+100% high quality+100% sincere service

    1. Specification

    Laser Nd

    YAG

    Wavelength

    1064nm/532nm

    Pulse energy

    1-1100Mj

    Pulse duration

    10ns

    Diameter

    2-6mm

    Cooling system

    Water cooling, wind cooling

    Net weight

    18 KG

    Voltage

    220V 50HZ,110V 60HZ

    2. Theory of operating
    The Q-switched Nd: YAG laser delivers a specific wavelength light with high energy which is absorbed by the pigment as tattoo and result in a shockwave. The shockwave shatters the pigment particles, releasing them from their encapsulation and breaking them into fragments small enough for removal by the body. Then these tiny particles will be eliminated by the body. This specific wavelength light can only be absorbed by pigment particles, so its no injury to the skin and the normal tissues will occur.

    3. Application
    A. For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal.
    B. For exogenous pigment: tattoo, eyeliner and eyebrow removal.
    C. Skin whitening.
    D. Striae gravidarum removal.4. Comparing5. Cautiona. Do not directly look at the hole of the laser gun; otherwise the blindness will be happened.

    b.Make sure the stopper must be revolved off before the water injection, and then keep the water flowing normally.

    c.Make sure it must be distilled water or purified water when injecting the cooling water intomachine,  tap water or mineral water is absolutely forbidden because it will result in water scale when heated, which will cause mechanical error of  machine.

    d.Make sure to check water circulation and joint between the machine and  hand-piece before running machine.

    e.The operation should be done when everything is ready. If there are any abnormal sounds, please stop working immediately; and lighten on again after the capacitance being charged up inside machine.

    f. Make sure the machine is absolutely discharged before transportation.

    This is April Wang. Thanks for your inquiry at  any time. Best service is waiting for you!

    Trade managee: cn220257150    Web: www.thefirstbeauty.com


    新しい到着の回入れ墨除去2011q- スイッチndレーザー美容機外因性の顔料のため除去と美白ceと-レーザーの診断装置 _レーザーの診断装置_医学レーザー装置_超音波、光学、電子機器_医療機器_健康と医療_仕入れ_問屋・仕入れ・卸・卸売り
    その他の製品


    line で相談する
    で相談する