製品情報
標準的なか標準外: 標準 | 圧力: 他 | 力: 他 |
材料: 黄銅 | 媒体の温度: 高温 | 媒体: 水液体ガス |
原産地: 中国(本土) | モデル番号: Ssvsv-gsvシリーズ | 銘柄: 風神 |
アイテム: ソレノイドバルブ |
包装
包装: ソレノイドバルブ: カートンのパッキングを持つ、 oemのパッキングにも出来るお客様のニーズに合わせた。 |
仕様
最大ソレノイドバルブ。 使用圧力: 3300mpa最大。 試験圧力: 3.5mpa
solenoid valves
Advantage:
1.varies types of solenoid valves
2 .with diaphragms
3. can be widely used in refrigeration, pneumatic and hydraulic system, also in boiler and fire-fighting, etc.
4. use full closed magnetic coil and DIN international standard electric plug.
5 good insulation, waterproof, moisture proof, anti-vibration and corrosion resistance.
Operating principle
1.When the coil is energized, the electromagnetic power opens the small orifice.
2.Then the pressure in upside of valve will reduce, the pressure difference between both side of diaphragm happens
3. and make diaphragm lift to open the main orifice.
4. When the coil is de-energized,the plug stem will drop and close the small orifice because of spring force and its weight.
5.The medium enters into upside of diaphrgm through throttle hole,
6.then the pressure in both side of diaphragm will downside.
7.Finally the diaphragm will drop and close the main orifice.
Usage
1. The valve must install in horizontal pipe line under vertical position. The flow direction must meet the arrow direction in valve body.
2. The oil input voltage must meet rated input voltage showed on the label. Departure coil from valve when energized in coil is not permitted in order to avoid damage the coil.
3. According to valve with manual function, it must turn manual bar to open the valve before doing system air tightness in order to avoid to damage diaphram.
4. When brazing the valve with connect tube in system, follow points are very important:
a. Before brazing, coil must be departure and use wet fabric cover the valve body to avoid to damage valve part because of high temperature when brazing.
b. It must avoid the brazing flame face to valve body.
c. It is better to adopt low temperature type silver brazing bar.
5. According to valve with manual function. The manual bar must be turned to open the valve before doing system air tightness, in order to avoid to damage the diaphram.
6. Coil must be set to the body when the current on.
Technical data
Ambient temperature: -20 ~ 50°C
Liquid temperature: -25 ~ 120°C
Max. working pressure: 3MPa
Max. testing pressure: 3.5MPa
Available medium: R134a,R22,R407C,R404A/507
Rated power:
A.C.: 24V,36V,110V,220V,380V
D.C.: 12V,24V,110V,220V
Type & data
Connection form | Model | Connection dimension | Kv value (m3/h) | Opening diff. pressure(MPa) | Dimension (mm) | |||||
(mm) | (in.) | Min | Max | |||||||
A.C. | D.C. | Length | Wide | Height | ||||||
Flare SAE | SV6 | Φ8 | 5/16 | 0.4 | 0.005 | 2.1 | 1.7 | 85 | 45 | 97 |
SV8 | Φ10 | 3/8 | 1 | 0.005 | 2.1 | 1.7 | 85 | 45 | 97 | |
SV10A | Φ12 | 1/2 | 1.8 | 0.005 | 2.1 | 1.7 | 85 | 45 | 97 | |
SV13A | Φ16 | 5/8 | 3 | 0.005 | 2.1 | 1.7 | 89 | 45 | 97 | |
SV16 | Φ19 | 3/4 | 4.5 | 0.005 | 2.1 | 1.7 | 118 | 60 | 120 | |
SV19 | Φ22 | 7/8 | 5 | 0.005 | 2.1 | 1.7 | 118 | 60 | 120 |
The Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa,ρ=1000kg/m3 Letters after the model: “A” means improved typr, “W” means solder ODF. “K” means normal opened valves. |
Connection | Model | Connection | Kv value | Opening diff. | Dimension | ||||
Min. | Max. | ||||||||
A.C. | D.C. | Length | Wide | Height | |||||
Flare | SSV6 | 5/16 | 0.4 | 0.005 | 2.1 | 1.7 | 85 | 45 | 97 |
SSV8 | 3/8 | 1 | 85 | 45 | 97 | ||||
SSV10A | 1/2 | 1.8 | 85 | 45 | 97 | ||||
SSV13A | 5/8 | 3 | 89 | 45 | 97 | ||||
SSV16 | 3/4 | 4.5 | 119 | 60 | 120 | ||||
SSV19 | 7/8 | 5 | 119 | 60 | 120 | ||||
Solder | SSV6W | 5/16 | 0.4 | 125 | 45 | 97 | |||
SSV8W | 3/8 | 1 | 125 | 45 | 97 | ||||
SSV10AW | 1/2 | 1.8 | 125 | 45 | 97 | ||||
SSV13AW | 5/8 | 3 | 150 | 45 | 97 | ||||
SSV16W | 3/4 | 4.5 | 185 | 60 | 120 | ||||
SSV19W | 7/8 | 5 | 190 | 60 | 120 | ||||
SSV25W | 1-1/8 | 9.5 | 0.03 | 232 | 72 | 120 | |||
1-3/8 | 250 | 72 | 120 | ||||||
SSV32W | 1-3/8 | 15 | 281 | 86 | 130 | ||||
1-5/8 | 281 | 86 | 130 | ||||||
The Kv value is the water flow in m3/h at a pressure dro across valve of 0.1MPa,ρ=1000 kg/m3 |
solenoid valves SV-G series water supply system :
SV-G series solenoid valves can be used as actor of automatic system in water supply system, fire control system, and water spray system in dirty proofing or agricultural. They also can be used for pneumatic hydraulic and food machine.
Solenoid valves use full-closed magnetic coil and DIN international standard electric plug, so it is characterized by its good insulation, waterproof, moisture proof, anti-vibration and corrosion resistance.
Operating principle
While energized in coil, the electromagnetic power opens the small orifice. Then the pressure in upside of valve reduced, so the pressure difference between both side of diaphragm happen and lead to diaphragm lift to open the main orifice. While de-energized in the coil, plug stem will dro and close the small orifice because of spring force and its weight. The flow media enters into upside of diaphragm through throttle hole, then pressure in both side of diaphragm balances, then the diaphragm will dro and close the main orifice.
Technical data
Ambient temperature: -20 ~ 50 .C
Medium temperature: -25 ~ 120 .C
Max. working pressure: 3 MPa
Available medium: R134a,R22,R407C,R404A/507,air,water and oil.
Optional voltage of solenoid coils:
A.C.: 24V,36V,110V,220V,380V.
D.C.:12V,24V,110V,220V
Type and data
Connection | Model | Connection | Kv value | Opening | Dimension(mm) | ||||
Min. | Max. | ||||||||
A.C. | D.C. | Length | Wide | Height | |||||
Internal | SV1/4G | G1/4 | 1 | 0.005 | 2.1 | 1.7 | 80 | 45 | 100 |
SV3/8G | G3/8 | 1.8 | 80 | 45 | 100 | ||||
SV1/2G | G1/2 | 3 | 68 | 45 | 100 | ||||
SV3/4G | G3/4 | 5 | 120 | 58 | 119 | ||||
The Kv value is the water flow in m3/h at a pressure dro across valve of 0.1MPa,ρ=1000 kg/m3 |