    WMS-70 Handheld/Portable Patient Monitor:

     

    Features:

    Routine Check Mode and Continuous Monitoring Mode
    Data Graph and Trend Table Review
    Rich Analysis Report
    Sync with PC based Software (WinXP and WinVista)
    lightweight and easy-to-use portable unit
    Built-in NIBP module
    Automated & on-demand NIBP measurements
    User or system-defined inflation pressure
    ECG is optional

     

    NIBP:

     Performance Specifications
    Display:3.5" Color TFT
    Resolution:320240
    Display Mode:Standard face, Waveform face                
    Indicator:Power indicator light, Alarm sound, Pluse tone
    Interface:socket for connecting sensors and sockets for communication cables
    Power Supply:DC 5V, <300mA
    Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours for continous working.8 hours for standby mode
    Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
    Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
    Alarm:Ajustable High and Low limits. Three level audible and vistual alarm
    User Configuration:All the color of parameters and waves can be set according to user's willing

     

    Technical specifications:

     

    Safety
    Meet the requirment of IEC60601 series
    Type of Protection:Class II with internal electirc power supply
    Degree of Protection:BF
    Dimention and Weight
    Dimention:145(W)x95(H)x37(D)mm
    Weight:400g(with battery)
    Operation Environment:
    Temperature:0~ +40 centi-degree
    Humidity:15% ~ 95%
    Storage Environment:
    Temperature:-20~ +60 centi-degree

    Humidity:10% ~ 95%        
    Patient Range
    Neonate ,Pediatric and  Adult

     

    SPO2:

    Measurement Range:0 ~ 100%
    Resolution:1%
    Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
                   ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
    Alarm Range:0% ~ 100%
    Refreshing Rate:1s

    Pulse Rate:

    Measurement Range:25 ~ 250 bpm
    Resolution:1bpm
    Accuracy:±3 bpm (non-motion)
    Alarm Range:25 ~ 250 bmp
    Refreshing Rate:1s

     

    NIBP:

    Method:Oscillometry
    Mode:Manual/Auto/Contiuous
    Measurement Range:25 ~ 260mmHg
    Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes
    Resolution:1mmHg
    Overpressure Protection: 300mmHg
    Alarm range: 25 ~260mmHg