• マルチ- パラメータ患者モニタ-医学マイクロ装置
    商品番号: 9803689
    仕入れる商品へのお問い合わせについて、
    お電話の場合:スタッフに商品番号をお伝えください。
    商品の詳細

    原産地: 中国(本土) 銘柄: JUMPER モデル番号: BF-800A 7
    タイプ: 医学マイクロ装置 Working Temperature: 0 ~ 40 Transport and Storage: -20 ~ 60
    Working Humidity: <= 85 % Transport and Storage Humidity: <= 93 % Working Altitude: -500 to 4,600m(-1,600 to 15,000ft)
    Transport and Storage Altitude: -500 to 13,100m(-1,600 to 43,000ft) Power Supply: 100~250 (V)AC, 50/60 (Hz)

    包装

    包装: 41*27*347kg/カートン

    仕様

     

      ultrasonic doppler fetal detactor  7 inches
     

    B.1 Basic parameters 

     

    ECG, RESP, NIBP, SpO2, PR, TEMP, Optional: Printer, IBP, FiCO ultrasonic doppler fetal detactor ultrasonic doppler fetal detactor 2, EtCO2,.

    B.2 Average working time without malfunction

       Average working time without malfunction: ≥ 1000 hours.

    B.3 Normal working environment

    a)    Temperature Range: (5 ~ 40)°C

    b)    Relative Humidity: ≤ 80 %

    c)    Air pressure range: (86~106)kPa

    d)    Power voltag AC: 100 V -240V

    e)    Power frequency: 50/60Hz.

    g)    Battery: d.c 10.2 V ~ d.c 12.6 V

    B.4 Safety requirements and classifications

    1. Electric shock type: type I equipment with inside power supply and internal power supply.
    2. Electric shock degree: all application parts are BF type, except ECG and TEMP which are CF type.
    3. Harmful liquid material proof degree: ordinary equipment (no seal against liquid).
    4. Disinfection: follow manufacturer’s recommended methods.
    5. Safety on flammable gas: not suitable to use wher flammable gas is present.
    6. Input power: no bigger than 80VA.
    7. The monitor has applicable
    8. The monitor has network, display, printer, and USB ports.
    9. Power supply is AC 100V-240V 50/60 Hz
    10. The monitor is a continual working system.

    B.5 ECG

    (HR)heart rate:

    a) measurement range: 30 bpm ~ 300 bpm

    b)        measurement accuracy: 1 bpm or ±1%, take the bigger one.

    Settings and allowable tolerance for HR alarm:
       Upper limit: 60 bpm~ 300bpm,allowable tolerance ±10%
       Lower limit:30 bpm~ 200bpm,allowable tolerance ±10%

    HR alarm response time: <12s

    ECG noise: ≤ 30μV
    ECG frequency response:

    Monitoring mode: (0.5 ~ 40)Hz (+0.4dB -3Db)

    Diagnostic mode: (0.05 ~ 100)Hz (+0.4dB -3dB)

    ECG input loop current: ≤0.1μA.

    ECG display sensitivity: Step-type

    ×1 step   10mm/mV         tolerance less than ±5%
    ×1/2 step   5mm/mV         tolerance less than ±5%
    ×1/4 step   2.5mm/mV       tolerance less than ±5%
    ×2 step   20mm/mV         tolerance less than ±5%

    Display sensitivity:

    a)         Time shift: initiate at the baseline after 15min's energizing.The shift scope of the baseline is not beyond 5mm after 60min's.

    b)        Temperature shift: the scope is from 5°C --40°C.The shifting average of baseline should be no more than 0.5mm/°C.

    c)         The shift of waved baseline of supply voltage should be no more than 1mm. The sensitivity changes should be displayed ±10%

    d)        The poling voltage at ±300mv is added between positive electrode and N electrode, negative electrode and N electorde. The changes of sensitivity error should be displayed ±5%

    Scanning velocity and error

    Scanning velocity: 6.25 mm/s, 12.5 mm/s, 25 mm/s, and 50 mm/s.

    Scanning velocity error: ±10%.

    Input impedance: The impedance between positive electrode and the N electrode, between thecathode and the N electrode is no smaller than 5MΩ.

    Module signal suppression ability: ≥89 dB

    Time constant: Diagnostic mode ≥3.2 seconds

                 Monitoring mode ≥0.3 seconds

    B.6 NIBP

    Measurement range

    a) Adult    Systolic blood pressure(SBP): (5.3 ~ 36.0)kPa,or(40 ~270 )mmHg

    Diastolic blood pressure(DBP): (2.7 ~ 26.7)kPa,or(20 ~200 )mmHg

    Mean average pressure(MAP): (4.0 ~ 29.3)kPa,or(30 ~220 )mmHg.

    b) Pediatric Systolic blood pressure(SBP): (5.3 ~ 24.0)kPa,or(40 ~180)mmHg

    Diastolic blood pressure(DBP): (2.0 ~ 21.3)kPa,or(15 ~160)mmHg

    Mean average pressure(MAP): (2.7 ~ 22.7)kPa,or(20 ~170)mmHg.

    c) Neonate   Systolic blood pressure(SBP): (4.0 ~ 18.7)kPa,or(30 ~140)mmHg

    Diastolic blood pressure(DBP): (2.0 ~ 13.3)kPa,or(15 ~100)mmHg

    Mean average pressure(MAP): (2.7 ~ 15.3)kPa,or(20 ~115)mmHg.

     

    Measurement accuracy: ±0.4 kPa (3 mmHg) or ±2%,take the bigger one.

    Display unit: KPa or mmHg.

    B.7 IBP

    Measurement range: (- 5.33 ~ + 44.0)kPa,or(-40 ~ + 330 )mmHg

    measurement accuracy: 4 % or ± 0.5 kPa,take the bigger one.
    display unit: kPa or mmHg are electable.

    B.8 RR

    Measurement range: (0 ~ 120 )bpm Measurement accuracy: ±1 bpm or ±5 %,take the bigger one.

    B.9 TEMP

    Measurement range: 25°C~ 45°C

    Measurement accuracy: ±0.2°C

    Response time: ≤3 min.

    B.10 SpO2

    Measurement range: 0 %~ 100%

    Measurement accuracy: ±2% during 70 %~ 100%, not required during 0 %~ 69%.

    B.11 PR

    Measurement range: 30 bpm ~ 250bpm

    Measurement accuracy: 1 bpm or ±2%. Take the bigger one.

    B.12 CO2

    Measurement range:

    FiCO2 and Et CO2:   (0 ~ 10.0)%

    measurement accuracy:

    FiCO2 and Et CO2: 0~5% ±0.2%

    5.1%~10%±8% of reading

    >10% ±10% of reading

     

                            

     

     

     

                             