製品情報
原産地: 台湾 | 銘柄: st | モデル番号: st530 |
タイプ: ネットワーク | 周波数: Mfは13.56mhz | 防水: はい |
包装
包装: 梱包カートン抗- 静的袋保護された |
仕様
防水のアクセスコントロールirリモート制御プログラミングを使用して暗号化し独立したドアの輸送システムledインジケータ
None Keypad Network Waterproof Access Control
IR Remote Control Programming
- Using encrypt transport system
- LED indicator
- None Keypad
- Independent Door Ring Bell
Specification
Power Supply | 12-15V DC / 250mA | Relay Output | 125V AC / 5A |
Dimension | 120 (H)*75 (W)*29 (D)mm | Material | ABS Shield |
Reading time | Less than 300 ms | Speed | 9600 Baud rate, N, 8, 1 |
WG Code | WG26,WG34 | Card No. | 8H10D(ABA), WG Code |
Operating Temp. | -20°C ~ 70°C | ||
Communication | RS485 port for PC Communication | ||
Radio Frequency | Mifare 13.56 Mhz match ISO14443A about 6cm. | ||
Triple crash avoids | Watching Dog for time, power supply, pulse detect (built-in error detect to avoid system or CPU crash.) | ||
Immunity | Capable multiple filter and anti-noise interference can isolate external interference. | ||
Data storage | Flash RAM with 2M memory can read and rewrite million times, EEPROM 512K. Reserve record and timer more than 30 days if power off. | ||
ST MF Encryption | Using encrypts transport system, when reading the card, through ST MF encrypts system to twice encrypt the readers and cards could increase the security of door access control. |
Feature
None keypad | Read card and patrol card only. | |
Door Ring Bell | Independent button connect to door bell. | |
3 LED Indicators | Red (error or in reading), Orange (system standby), Green (access) | |
Two Relays | Output for door opening and expansive output. (30V DC / 5A) | |
Records to Attendance | Access records for the evaluation of attendance. | |
RS-485 ports | For PC connection. | |
Model | ST530 | |
Mode | S1 Mode | S2 Mode |
Card Capacity | 1,000 | 65,535 |
Record Storage | 1,000 | - |
Door Group | 15 | - |
Standalone/Networking Function (Programming)
(Programming through PC Connection or IR remote controller)
Access modes | Read card only or patrol card. |
Master Card | Sense and enter programming mode directly, acitivate new cards/tags by sensing. |
Repeat Card interval | It’s for prevent repeat reading. It can set 1 to 255 seconds |
Door (Open) Relay time setting | It can set 0.15 to 250 seconds, 251 = 0.15s, 252 = 0.3s, 253 = 0.45s …etc. 0 = keeping, one time on, one time off. |
Free Access Time Zone | Free access time zone and elevator free access time zone. |
Firmware update | updat firmware through RS-485. |
System reset | Could clear parameter or restore to factory defaults by command. |
Remote control extension | Connect with remote control reader could receive signals from remote controller and respond to PC. |
Extensive reader | It connects to reader and perform anti-pass back funciton. It also can integrate different WG devices into ST system. |
Access info resetting | Function for the anti-pass back info reset time. |
Fire control linking | Connect the fire alarm or ST-916E/Ei DI linking, when detect the fire, open all the doors. |
Warning output | Alarms for anti-threat (with anti-threat code), controller is forced to remove, opening over time, forced entry. (With Door reed sensor) |
Open overtime alarm | It can set from 1 to 255 seconds. |