製品情報
原産地: 中国(本土) | 銘柄: 新郷丹東 | モデル番号: dp802i |
測定範囲: Dos率0.01usv/h~150msv/h | エネルギー応答エラー: +- 30%( 相対137csに) | エネルギーを範囲: 40kev~1.5mev |
累積線量を: U0sv~999.99msv | 図形のサイズ: 90*60*17mm | 重量: 66グラム |
電源: 7バッテリーを使用してい | 保護アラーム応答時間: 秒1~2( 最も速い) |
包装
包装: 漫画のケース--- 丹東新郷硬さ試験機 |
仕様
ポータブル工業用放射線線量計1.輸入部品2.最高品質3.長寿命
Product Description
Dandong xinxiang radiation dosimeter
ABSTRACT
DP-802i X and gamma radiation individual dose equivalent (rate) monitora humanized design, enhanced personal dose monitoring is mainly used for radiation protection monitoring of X, and hard beta gamma ray, suitable for power plant, accelerator, isotope application, industrial x. gamma, nondestructive testing, medical radiaton (iodine, technetium resources, the field of nuclear facilities in the surounding environment montoring, timely alarm indication, ensure the safety of staff.
Features
- Humanized design, large liquid crystal display, simple operation, convenient.
- High sensitivity , can measure the environment background
- Cumulative does and dose rate at the same time measurement and display, but also can measure CPM
- Automatic switching unit of measurement, the measurement data of intelligent storage
- Automatically save the cumulative dose and cumulative start date
- The cumulative dose, dose rate and places of detention time alarm function
- Dose rate alarm can be preset and cumulative dose alarm threshold
- Sound , vibration , light , silent alarm way any combination of selected
- Design of low power consumption, the power supply voltage of the battery status indicator
- With real-time clock function, shut off the clock running
- After the failure of long time preservation instrument data, can be stored date alarm and alarm value
- Built-in fault detection, dose rate overload alarm and protection function, to ensure the normal work of the instrument
Main technical indicators
l Measuring range: dos rate:0.01 µ Sv/h ~ 150mSv/h
l The cumulative dose: 0 µ Sv ~ 999.99 mSv
l The energy range:40Kev ~ 1.5 Mev
l Energy response error: ± 30% (relative to 137Cs)
l The relative basic error: ± 10%
l The measurement of time: the measurement time automatically selected according to Xray intensity, faster response speed
l Alarm threshold :0.5 ,1.0 ,2.5 ,10 ,30 ,50 ,100.......5000 µ Sv/h
l Protection alarm response time:1-2 seconds ( the most fast )
l Display units: dose rate ( Sv/h or mSv/h or Sv/h ) and cumulative dose ( SV )
l Power supply : use a 7 battery, low power consumption, this measure can be used within 20 days ( normal working hours )
l Shape size: 90×60×17mm
l Weight : 66 g