原産地: 中国(本土) | 銘柄: PROCET | モデル番号: PT-PSE100 |
Brand: PROCET | Type: PT-PSE100 | Port: one port for data, one port for LAN |
Input Voltage: 100-280VAC | Output voltage: 48VDC/630mA | Power: 30W |
bandwidth: 10/100Mbps |
包装
包装: Neutral packing or as your needs Packing Volume:160*65*40mm GW:160g Neutral packing or as your needs |
one port POE injector Features and Functions
ROCET PT-PSE100 is a single-port integrated power sourcing equipment.,and working well during input voltage 100VAC~240VAC.This power supply use CAT5E cable to connect to other network terminal equipment, working with 10/100M network environment.
Model | PT- PSE100 |
Load regulation | 48VDC±5% |
No. of Ports | 1 Port |
Pass Through Data Rates | 100/1000M |
User Port Power | 30 Watts |
Power over Ethernet Output Pin Assignment and Polarity | 1/2(+) 3/6(-) or (4 5+ 7 8- ) |
Input Power Voltage | 100 ~ 280V AC |
Output Power Voltage | 100 ~ 280V AC |
AC Frequency | 50 ~ 60HZ |
Connectors | Shielded RJ-45, EIA 568A and 568B |
Dimensions | 134 (L) x56 (W) x 33 (H) mm |
Weight | 150g |
Operating Ambient Temperature | -15 to 55 °C |
Reliability MTBF | >100k hours |
Relative humidity | 5%~90%RH |
DC output voltage | 3.4kHz~150kHz≤50mv |
PROCET PT- PSE100 Performance:
1.The power supply provides output voltage over-voltage and overload protection.
2.System reliability:MTBF>100k hours
3.Conducted interference(CE)and Radiated interference(RE):confirm to EN55022,CLASS B standard.
4.Lightning protection: AC input port can take 1.5KA, 8/20uS surge pulse current for 5 times,with interval of 1 minute.
5.Cooling method and air cooling
6.Noise:<50dB
7.Open after 5 seconds, output voltage normally.
Environmental Specifications
1. Operating Temperature:-5°C~+55°C
2. Relative Humidity:5%~90%
3. Places that are ventilated and heat dissipation well, clean, no conductive dust, no corrosive gases.
4. Places without explosion hazard.
Remote power supply protection
Range of output over-voltage protection: -52VDC~-50VDC
Over-current protection(Single circuit): 350Ma~400Ma
Over voltage protection: Input voltage over 290VAC~310VAC
Over voltage recovery point: Input voltage over 285VAC
Under voltage protection: Input voltage under 80VAC~85VAC
Under voltage recovery point: Input voltage under 90VAC
Over-temperature protection:>100°C
Ethernet ports light instructions
LED instructions
PWR ON: work properly.
Indicates overload or short-circuit if the green light a few seconds and then turns off.
Installation and Commissioning
1.Plug the input power cord into the 220VAC input socket.
2.Connect to the output signal line
3.Check the connection of lines and ports connected tightly to avoid bad contacts and loose
Notice
1. Installation site must be kept away from heat sources,electromagnetic interference, non-corrosive gas and me-tal dust.
2. Keep equipment louver ventilative.
3. Keep steady when installing.
4. Taking care input voltage is between 100VAC-240VAC
5. Avoid collision and friction. .
Storage
Storage should be on the dry warehouse, not exposure and rain.
Storage temperature:-5°C~+55°C (Low temperature storage recovery time at least 4 hours)
Relative humidity:5% ~90%RH