原産地: | 中国(本土) | LEDの光源: | led照明 | 銘柄: | sharplumi | CRI (Ra>): | 80 | 入力電圧(V): | 85-265 | ランプの明るい効率(lm/w): | 100 | 認証: | CE, CCC, RoHS | ランプの光束(lm): | 1000 | ランプボディ材料: | アルミ合金 | ランプ力(W): | 10 | 働く寿命(時間): | 50000 | 働く温度(℃): | -20 - 60 | 保証(年): | 2 | 色温度(CCT): | 2700-6500 | IPの評価: | IP44 | 光源: | LED | 項目タイプ: | 管はつく | ライト: | 緩やかな変化 | 素材: | pvc | サイズ: | 26*911ミリメートル(以内二つピン) | 視野角: | 120 ° | correled数量: | 480 leds | 入力電圧: | ac85-265v | 形状: | シリンダー | チューブカバー: | 透明カバー&ミルク入り江 | ヘッド: | 170回転可能なヘッド&非腐敗 | ledタイプ: | 高輝度smd2835 |
包装
包装: | 1。0.6メーター、35ピースカートン、69*34*22 2. your梱包suggestiosは歓迎。 |
0.9meter led tube (dimmable)
led tube specification
Item No. | Color | WB/CT | QTY/M | Luminous flux( LM) | Power | CRI(RA) | size(MM) | Life Span(H) | Voltage(V) | PF(%) |
ST8-3528-W200A | white | 5800-6200K | 200 | 1416 | 14 | 80 | 26*905 | 60000 | AC85-265 | 0.96 |
ST8-3528-WW200A | Warm white | 3800-4200K | 200 | 1365 | 14 | 80 | 26*905 | 60000 | AC85-265 | 0.96 |
ST8-3528-WW200B | Warm White | 2800-3200K | 200 | 1200 | 14 | 80 | 26*905 | 60000 | AC85-265 | 0.96 |
ST8-5050-W80A | White | 5800-6200K | 80 | 1180 | 15 | 80 | 26*905 | 60000 | AC85-265 | 0.96 |
ST8-5050-WW80A | Warm white | 3800-4200K | 80 | 1300 | 15 | 80 | 26*905 | 60000 | AC85-265 | 0.96 |
ST8-5050-WW80B | Warm White | 2800-3200K | 80 | 1050 | 15 | 80 | 26*905 | 60000 | AC85- | 0.96 |
1. There is No harsh glare, directly replacement for Traditional Fluorescent T8.
2. Integrated thermal management system.
3. Longlife time 50, 000 hours under normal use, especially for office lighting.
4. Optimized light extraction system delivery high lumens.
5. No RF interference, Lead free.
6. Long lifetime - LED feature, reasonable driving, no effect from switch on/off.
7. Green environment, without any harmful materials listed in RoHS.
8. No need maintenance, long life of LEDs, no trouble of replac parts of normal fluorescent tube.
9. No flash, AC driving, stable light, protect eyes.
10. Easy mounting, can be mounted directly.
11. No need accessories, no need traditional driving and reflector parts.
12. Not easy broken, all materials from inner light sources and outer cases are hard materials, such as Epoxy, ABS, PC,
13. No electromagnetism interference, no high power switch and inductance parts, no environment electromagnetism pollution.
led tube Installation:
The same size tube can be installed on to the corresponding lamp holder directly before taking
down fluorescent lamp starter.
1. LED tube can be directly installed into T8 or T10 bracket(take down fluorescent lamp starter);
2. LED tube light apply to inductive light holder. Electronic ballast fluorescent tube can’t be replaced directly,should take down