SAKO SKN-H SERIES TECHNICAL PARAMETER |
| SKN-H600 | SKN-H1000 | SKN-H1200 | SKN-H1000 | SKN-H2000 | SKN-H2400 |
SPECIFICATION |
| DC INPUT |
Input Voltage (VDC) | 12VDC | 12VDC | 12VDC | 12VDC | 24VDC | 24VDC |
Input DC Range (VDC) | 10~15VDC | 20~30VDC |
| AC BYPASS (IN “ON/OFF” SWITCH OFF MODE) |
Input AC Range (VAC) | 220/230/240VAC |
177 - 280VAC (Narrow Range) or 90 - 280VAC (Wide Range) |
Input Frequency (Hz) | 50/60Hz |
Bypass Output Voltage (VAC) | Same As Input AC |
Bypass Output Frequency (Hz) | Same As Input Frequency |
Charge Current (A) | 10A ± 2A or 10A and 20A Selectable |
Charge Floating Voltage (VDC) | 13.75 ± 0.2VDC | 27.5 ± 0.4VDC |
Over Charge Voltage (VDC) | 15.0V ± 0.4V Charge Stop | 30.0V ± 0.8V Charge Stop |
AC Efficiency | > 97% |
Transfer Time (ms) | Typical 15ms |
| AC OUTPUT (INVERTER) |
Capacity (VA) | 600 | 1000 | 1200 | 1000 | 2000 | 2400 |
Output Power (W) | 360 | 600 | 720 | 600 | 1200 | 1440 |
Output Voltage (VAC) | 220VAC |
Output Frequency (Hz) | 50/60Hz |
Output Current (A) | 2.7/1.6 | 4.5/2.7 | 5.4/3.2 | 4.5/2.7 | 9.1/5.5 | 10.8/6.4 |
Voltage Precision (VAC) | 220VAC ± 10% |
Frequency Precision (Hz) | 50/60Hz ± 0.1Hz |
Wave | Modify Sine Wave |
Power Factor (PF) | 0.6 |
Inversion Efficiency | > 85% |
Bypass Transfer Time (ms) | <= 8ms |
Over Load Capacity | Over Load 110%, 60s Later Shut Off |
| PROTECTION |
Protection | Over load / short circuit protection / over charge / discharge Protection |
| AMBIENT |
Noise (dB) | <=40dB (1 Meter) |
Temperature | -20°C ~ 45°C Degree |
Humidity | 0~95% (No Condensation) |
Sea Level (m) | <= 1500m |
| DIMENSION |
Package L×W×H (mm) | L638*W370*H552 mm (10PCS In One Carton) |
G.W. (KG) / Carton | 26.5KG | 27.5KG | 27.8KG | 27.2KG | 28.2KG | 28.6KG |
|