原産地: | 中国(本土) | 銘柄: | MeCan | モデル番号: | MCA-302 air O2 NO2 flowmeters anesthetic ventilator machine | タイプ: | 麻酔の装置及び付属品 | Product: | 2 Vaporizers air O2 NO2 flowmeters anesthetic ventilator machine | Applied for adult and pediatric: | Integrated anesthetic ventilation system | LCD display ventilation parameters: | preset parameters alarm indication and breathing waveform | Pediatric to bariatric: | Electronically controlled, Pneumatic driven | Mode of ventilation: | VCN, SIGH, SIMV, Stand-by, Manual, PEEP | Monitoring: | VT, MV, BPM, Paw, FiO2, Lung compliance | Hypoxic guard system: | N2O cut-off valve, O2 concentration no less than 25% | No. of gases: | O2, N2O, air | 2 vaporizers: | Isofurane, Enfurance, Halothane and Sevoflurance as per option | Usage: | 2 Vaporizers 3 Gases Anesthetic Ventilator Machine for Surgical room |
包装
包装: | この標準輸出用木材梱包8.4" 液晶ディスプレイ2のぞき見気化器空気流量計モードfio2o2no2麻酔薬は人工呼吸器のマシンに適した海による配達やによって空気。 |
仕様
Air O2 NO2 flowmeters Anesthetic Ventilator Machine
Model: MCA-302
Main Feature of the Air O2 NO2 flowmeters Anesthetic Ventilator Machine:
1. Applied for closed, semi-closed, semi-open
inhalation anesthesia, controlled or
assisted ventilation, monitoring and
display patients’ ventilation parameters
2. Applied for adult and pediatric
3. Integrated anesthetic ventilation system,
APL security air relief valve is available
4. Vaporizers: 2. Advanced temperature,
flow and pressure compensation technology,
Isofurane, Enfurance, Halothane and
Sevoflurance as per option
5. 8.4” TFT-LCD display screen
Main Specification pf the Air O2 NO2 flowmeters Anesthetic Ventilator Machine:
Type: Electronically controlled, Pneumatic driven
Patient spectrum: Pediatric to bariatric
Mode of ventilation: VCN, SIGH, SIMV, Stand-by, Manual, PEEP
Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%
Safety valve: <12.5kpa
Monitoring: VT, MV, BPM, Paw, FiO2, Lung compliance
Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
Power: AC 220V±10%, 50Hz±2%, built-in battery support
Gas: O2, N2O, air
Alarm of the Air O2 NO2 flowmeters Anesthetic Ventilator Machine:
Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)
prompt and protection of the Air O2 NO2 flowmeters Anesthetic Ventilator Machine:
prompt for parameter limitations, protection for unreasonable parameter setting.