• 現在の位置: ホーム » 仕入れ » 測定器・分析器 » 光学機器 » 分光計 »
    金の含有量試験gd-4530fdetetor鉄原子吸光分光法-分光計
    商品番号: 11570482
    仕入れる商品へのお問い合わせについて、
    お電話の場合:スタッフに商品番号をお伝えください。
    商品の詳細

    原産地: 中国(本土) 銘柄: ゴールド モデル番号: GD-4530F aas原子吸収分光法
    焦点距離: 015ミリメートル 測定の範囲: 0-999 重量: 75キログラム
    サイズ: 700 × 550 × 450 (mm) 波長範囲: 190nm-900nm 装置: アトミック吸収分光計用金属分析
    使用法: 金属要素検出器/金属アナライザ分析計 アプリケーションフィールド: 臨床分析、医薬品、水分析 精密: 0.5%
    格子: 1800本/ mm スペクトル帯域幅: 変更間0.1、 0.2、 0.4、 1.0と2.0nm 精度の波長: ± 15nm
    保証: 1年

    包装

    包装: 金のための木製ケースdetetor鉄原子吸光分光法の含有量試験

    GD-4530F Gold Detetor Iron Content Testing Atomic Absorption Spectroscopy  

     

     

     

    Characteristics:

     

     Completely controlled by PC, can flexibly selec the flame and graphite furnace atomizer (optional)

     Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term. 

     Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp

     Position adjusting: the best height of the flame burner and can automatically set the front and rear positions

     Fully automated wavelength scanning and peak searching

     Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout

     Deuterium lamp and self-absorption background regulation 

     Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called

     Measuring method: flame absorption method and emission method

     Result printing: parameter printing, data result printing and diagram printing

     

     

    Complete Automatic Controlling System:

     

     With the help of the software, the following can be easily achieved

     Selection of the element lamp

     Up-down-front-rear adjustment of the lifter

     Adjustment of the optical energy

     Selection of the slit

     Determination of wavelength scanning and peak searching

     Selection of the atomizer

     Setting of the background deduction method 

     Controlling of the gas flow

     Automatic flaming and flaming out 

     Setting of the graphite furnace testing method 

     

     

    Advanced Graphite Furnace Temperature Controlling Technology

     

     The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by 

     the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 

     3m s/time fast sampling technique can make more accurate and reliable testing data

     The fast heating capacity can improve the flexibility of the elements further 

     Use the ordinary power source of 220V without need of dynamic power of 380V

     The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples

     Three grades adjustable gas flow can accustom to more application needs  

     Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error

     

     

    Safe, Reliable and Convenient Flame System    

     

     Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily 

     Efficient Atomization system enables a higher sensitivity 

     The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off 

     the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage. 

     

     

    Multi-functional Software Workstation 

     

     A workstation that is supported WINDOWS XP/2000/NT

     The rich menu brings great convenience to the use of customer

     Convenient conversion between different menus makes the operation more easily

     Various analytical correction methods provide the users more choices 

     Basic default parameter settings enable even the beginners can do the normal operation

     Flexible storage, editing and printing methods give the user largest support 

     Instrument configuration:

     Atomic Absorption Spectrophotometer   1pc

     Air compressor without noise            1pc 

     PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configurat ion)

     A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

     

     

    4530F:

    1Wavelength range190 – 900nm
    2Spectral bandwidthCan automatically change between 0.1nm,0.2nm,0.4nm,1.0nm and 2.0nm
    3Accuracy±0.15nm
    4Receptivity of the wavelength≤0.04nm
    5base line stability≤0.002A/30min (Cu)
    6Characteristic viscosity0.02μg/ml/1% (Cu)
    7Checking limit0.004μg/ml (Cu)
    8Preciseness0.50%
    9Grating1800 lines/mm
    10InflamerAll-metal titanium burner
    11AtomizerEffective glass atomizer
    12Lamp turretsEight lamps
    13Size and weight700mm×550mm×450mm 75Kg
    14Power source220V±22V AC

     

     

    Flame System:

     

     Acetylene air burner:100mm

     Nitrous oxide acetylene flame head:50mm

     Ignition dynamic baseline drift:≤0.006A/30min

     (Cu) Characteristic viscosity:≤0.025μg/ml/1%

     Related standard deviation of the accuracy:≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) 

     Safety system:Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

     

     

    Graphite Furnace:

     

     The highest temperature:3000°C

     The largest temperature rising speed:≥2000°C/S

     Characteristic quantity:Cd≤0.5×10-12g  Cu≤0.5×10-11g

     Accuracy:Cu≤3%  Cd≤3%

     Size and weight:550mm×450mm×300mm 65Kg

     Safety system:Over current protection 

     Low air pressure alarm / protection 

     Low cooling water flow alarm/protection

     Power source and power:220V±22V AC 7000W

     

     

     